01732 360 095

The Titan-Pro packaged sump system is designed specifically to be used with the Newton CDM System.

The adjustable neck allows for the sump to be installed at a fixed height relative to the slab so that the connection in from the Newton drainage system and the pump discharge line are made above the concrete, and always at the same height relative to the slab or raft.

The sump can be used with single and twin pumps and twin pumps with twin discharge lines for greater pump efficiency.

The unique sump shape together with a choice of inlet and outlet positions allow for connections in and out of the chamber to be made to either a side wall or to a corner.

  • Key Benefits
  • Typical Applications
  • Pump Configurations & Product Codes
  • Available across the UK
  • Key Benefits

    Key Benefits

    • Compatible with Newton CP pumps, NP pumps and NP eco pumps
    • Adjustable neck ensures that the lid is always at the correct height, regardless of floor finishes
    • Supplied with sealed and locked recess lid. High-end finish lids and frames are available as cost options
    • Flat areas to side of chamber, ready for wall flanges to receive incoming 110 mm drainage pipes. Wall flanges are available as cost options
    • Large foot to base of chamber to prevent flotation
    • Anti-Drip system available for the inside of the chamber
    • Sump is always set into the slab at the same height, meaning connections in from Newton Basedrain System and connections out of the chamber are at the same height with every installation

    Typical Applications

    Typical Applications

    • The Titan-Pro is specifically designed to be used with the Newton CDM System, our ‘Type C’ cavity drain waterproofing system
    • Basements and cellars
    • Light-wells
    • Surface water pumping receiving water from gullies and surface slot drainage

    BS 8102:2022 the British Standard for Waterproofing

    The British Standard 8102:2022 Code of Practice for Protection of Below Ground Structures Against Water From the Ground is the main design guide for structural waterproofing in the UK.

    Newton System 500 is a maintainable system, so complies with BS 8102 requirements. BS 8102 also specifies that “a waterproofing specialist should be included as part of the design team so that an integrated waterproofing is created”.

    Therefore it is our recommendation that the Newton CDM System is installed by a Newton Specialist Basement Contractor (NSBC).

    FAQ

    What does a sump pump actually do?

    A sump pump is a pump used to remove water that has accumulated in a sump basin, commonly found in the basement of homes. The pump is typically installed in the lowest part of the basement, or in a crawlspace, and pumps the water out of the home and away from the foundation.

    Where do sump pumps drain to?

    Sump pumps typically drain to a dry well, pond, or garden drain. Take care the drain is away from the home so the water will not end up back in the same place.

    Pump Configurations & Product Codes

    Pump Configurations & Product Codes

    The Titan-Pro chamber can be purchased as a bare sump or as a fully built pumping system. As a bare pump, it can be supplied with or without lid and frame and either pre-drilled and un-drilled.

    Sump Chambers

    If you only need a chamber or want to order your pumps separately, choose from our drilled and undrilled Titan-Pro chambers, both with and without lids.

    Code Drilled Lid Description
    TPC No No Titan-Pro Sump Chamber only
    TPCD Yes No Titan-Pro Sump Chamber – Drilled
    TPC&L No Yes Titan-Pro Sump Chamber with Lid
    TPCD&L Yes Yes Titan-Pro Sump Chamber with Lid & Drilled

    Sump Chambers & Pumps

    A Newton PA50 High Water Level Alarm is included with automatic pump systems.

    For more information on the individual pump units that can be ordered with the Titan-Pro chamber, call our Technical Team on 01732 360 095, or email tech@newtonwaterproofing.co.uk.

    Built Systems – Twin pumps – 1 x Rising main
    Code Pump Model No. of Pumps Auto or Manual Rising Mains
    CDM1 CP250 2 Automatic 1
    CDM2 CP250 2 Manual 1
    CDM3 CP400 2 Automatic 1
    CDM4 CP400 2 Manual 1
    CDM5 NP400 2 Automatic 1
    CDM6 NP400 2 Manual 1
    CDM5 eco NP400 eco 2 Manual 1
    CDM6 eco NP400 eco 2 Auto 1
    CDM7 CP750 2 Automatic 1
    CDM8 CP750 2 Manual 1
    CDM11 eco NP750 eco 2 Automatic 1
    CDM12 eco NP750 eco 2 Manual 1

    Where increased pump flow (pump duty assist) is required, twin rising main systems should be considered.

    Built Systems – Twin pumps – 2 x Rising main
    Code Pump Model No. of Pumps Auto or Manual Rising Mains
    CDM9 CP750 2 Automatic 2
    CDM10 CP750 2 Manual 2
    CDM13 eco NP750 eco 2 Automatic 2
    CDM14 eco NP750 eco 2 Manual 2

    Available across the UK

    Available across the UK

    Cavity Drain Waterproofing Solutions Across the UK

    We provide cavity drain waterproofing products and solutions across the whole of the UK:

    Speak to our friendly, expert team

    Our staff are able to provide guidance for projects of all sizes, whether you require some general advice about damp or waterproofing, or support with technical drawings and specifications.


      By submitting your details you confirm that you agree to the storing and processing of your personal data by Newton Waterproofing as described in the privacy statement.